EARTHING AND PROTECTION SYSTEMS
DATE: 12 & 13 APR 2011

VENUE: THE LEGEND KL

WORKSHOP

overview

This is a course intended to provide a comprehensive coverage of
substation earthing system design for safety and protection
systems. The course provides comprehensive coverage of earthing
system design and protection systems. A simplified coverage of the
basic principles in earthing design, which involve the measurement
and interpretation of soil resistivity, and some simple calculations
for the design of earth resistance for the substation are first
provided.
It is then followed by the operation of the protection systems which
include the operation of protection schemes, such as various circuit
breakers and power system protection relays. The issue of what
constitutes to an adequate design of the earthing and protection
systems will also be addressed.

WHO






WORKSHOP
should attend?

Electrical
engineers
who
are
responsible for electrical systems in
substation, maintenance, building
and industries.
Electrical contractors, plant engineers
and utility engineers
Electrical engineering technicians who
may not have formal electrical
engineering education.
Civil servants, executives, managers
and sales personnel dealing with
electrical engineering projects

www.comfori.com











objectives

To understand the concept of earthing systems.
To understand the earthing system design procedures and
performances
To have knowledge on the techniques used on the earth resistivity
and earth resistance measurements suggested in the standards
To understand definitions and calculations of ground potential rise
(GPR), touch, and step voltages.
To identify the types of fault
To understand and analyse the principles and operation of
protection schemes
To learn and analyse various circuit breakers
To understand the characteristics of various power system
protection relays
To understand the differences between analogue and digital
protection schemes

EARTHING AND PROTECTION SYSTEMS

asasasasasfhhjgjjkmnbdcfdsfdsfdsfsdadasfdesdfsdgvddsfcdfcd

SPEAKER’S

DR. NORMIZA MOHAMAD NOR received her
degree with First Class Honours in Electrical and
Electronic Engineering from University of Wales,
College of Cardiff, UK in 1996. She obtained the
Ph.D degree in Electrical Engineering from the
same university in 2001. She became a research
fellow for almost a year to Telekom Research and
Development Sdn Bhd to advise on the project
related to earthing systems under high impulsive
currents. She has also delivered a seminar on the
earthing systems and protection to the technical
staff of Malaysia Airport Berhad. She has so far
published 20 international journals and
conferences. She is currently a lecturer of Electrical
Engineering at the Multimedia University,
Malaysia. Her research interests include high
voltage, earthing systems and lightning protection.

PROFILE

DR. KARTIK PRASAD BASU was born in India in 1940. He obtained his
B.E.E., M.E.E. and Ph.D. (Eng.) degrees from the Jadavpur University,
Kolkata, India, in 1961, 1967 and 1974 respectively. He is a Senior
Member of IEEE (USA) and Fellow of IE (India). He worked as Engineer
in Electrical Contractor’s firm and in Power Supply Company in India
for about 4 years. He has the extensive experience of Electrical
Installation works in industries and commercial buildings. He also
gathered working experience of operation and maintenance of High
Voltage Generation, Transmission and Distribution.
Dr. Basu possesses more than 39 years of experience in teaching
Electrical Engineering courses in the area of Electric Power. He
worked in premiere universities in India and Libya in senior teaching
positions and also worked as Chairman of a department for 3 years.
Presently he is working as Associate Professor in the Multimedia
University, Cyberjaya, Malaysia. He is also engaged in valuable
research work and published more than 60 technical papers in
reputed international journals/conference proceedings of USA, UK,
Switzerland and India etc.
Assoc. Prof. Basu was awarded twice with Best Research Paper
Awards. He is also a reviewer of technical papers of some
international journals. In addition, he also worked as consultant to
private companies. Dr. Basu delivered lectures to practicing engineers
in large number of short courses, seminars and workshops in India
and Malaysia.

www.comfori.com

EARTHING AND PROTECTION SYSTEMS

WORKSHOP OUTLINE
DAY 1- EARTHING SYSTEMS BY DR. NORMIZA

Module 1: Basic Concepts
 Recommended Earth Impedance Value
 Earth Equivalent Circuit Representation
Module 2: Factors Involved In Effective Earthing
 Soil Resistivity
 Types of Soil
 Moisture content
 Soil temperature
 Chemical Content.
 Installation of ground enhancement materials
 Measuring installed grounding systems.
 Maintenance of the grounding system
Module 3: Earth Electrodes
 Shape on Electrode Resistance
 Selection of a Material for an Earth Electrode
 Corrosion and Type of Soil
 Corrosion due to interconnection with
another metallic item
 Other Considerations
Module 4: Design Overview
 Design considerations
 Design procedure
Module 5: Soil Resistivity Measurements
 Equally spaced or Wenner Method
 Unequally-spaced or Shlumberger-Palmer
Arrangement
 Interpretation of the Measurements
 Master Resistivity Curve
 Curve Matching Method
Module 6: Earth Resistance Measurements
 Fall of Potential Method
 Methodology

www.comfori.com

DAY 2 – PROTECTION SYSTEMS BY DR. KARTIK

Module 7: Fault Studies
 Types of faults
 Symmetrical fault analysis
 Unsymmetrical fault analysis
 Fault current reduction
 Case studies
Module 8: Power System Protection
 Introduction to Protection
 Fault detection principles
 Basic components
Module 9: Circuit Breakers
 Creation and extinction of arc
 Types of circuit breakers: air, air-blast, oil,
vacuum, SF6
 Rating, selection of CB
 Testing
 Auto-reclosing CB
 MCB
 Fuses: rewireable, cartridge, HRC
Module 10: Protective Relaying
 Over current, earth fault, over load,
differential, distance relays
 Buchholz, temperature sensitive relays
 Equipment protection
 Transformer
 Generator
 Transmission and distribution line
 Motor
 Digital Protection
 Computer/Microprocessor based protection
algorithm for over current, differential,
impedance relays

EARTHING AND PROTECTION SYSTEMS

WORKSHOP VENUE

PLEASE COMPLETE THIS FORM AND FAX TO US
AT 03-5638 8248 (ATTN: ‘AABID BAHARUDIN)
PARTICIPANTS INFORMATION
NAME:_____________________________________
POSITION:_________________________________________
EMAIL:____________________________________________
H/P NUMBER:______________________________________
OFFICE (DIRECT LINE):_____________________________
NAME:_____________________________________
POSITION:_________________________________________
EMAIL:____________________________________________
H/P NUMBER:______________________________________
OFFICE (DIRECT LINE):_____________________________
NAME:_____________________________________
POSITION:_________________________________________
EMAIL:____________________________________________
H/P NUMBER:______________________________________
OFFICE (DIRECT LINE):_____________________________
NAME:_____________________________________
POSITION:_________________________________________
EMAIL:____________________________________________
H/P NUMBER:______________________________________
OFFICE (DIRECT LINE):_____________________________

THE LEGEND HOTEL, KL
100, Jalan Putra, 50350 Kuala Lumpur
Tel: 60-3-4042 9888

For reservations, please make your bookings directly with the
hotel. To enjoy special room rates, please quote Comfori’s
Workshop on:
FE011-EARTHING AND PROTECTION SYSTEMS, 12&13 APR 2011
Hotel bills are to be settled by delegates directly with the hotel.
Hotel reservations and travel arrangements are the
responsibilities of the registrant. Please note that rooms are
available at a first come first serve basis.

WORKSHOP FEE

PRICE

APPROVING MANAGER
___________________________________________________
ADDRESS
_____________________________________________________
_____________________________________________________
_____________________________________________________
_____________________________________________
TEL NUMBER
___________________________________________________
FAX NUMBER
___________________________________________________
HR CONTACT & EMAIL
___________________________________________________
SIGNATURE & COMPANY STAMP

RM 2690/PAX

3 – 5 PAX

RM 2490/PAX

≥ 6 PAX

RM 2290/PAX

Please note that the Certificate of Attendance will only
be given to the participants after payment received

COMPANY’S INFORMATION
ORGANIZATION

__________________________________________

1 – 2 PAX

MODE OF PAYMENT
Cheque or bank draft in favour of:

COMFORI SDN BHD (581115-T)
E-02-03, East Wing, Subang Square Business Centre
Jalan SS15/4G, 47500,Subang Jaya, Selangor,Malaysia
Tel: +(603) 5621 3630 Fax: +(603) 5638 8248
Website: www.comfori.com
Payment Via:
Cheque by post/courier
Tele Transfer
Deposit Our Account (A/C No. : MBB 5123-5260-0832)

SBL CLAIMABLE
Please note that payments must be received within
7 days upon issuance of invoice

TERMS & CONDITIONS
Cancellations & Substitutions. All cancellations must be made in writing at least 14 days in advance, and COMFORI SDN. BHD. reserves the right to
charge a RM250 hotel booking fee. Cancellation less than 7 days will be charged the full course fee. Substitutions are welcomed at anytime. However, please
inform us at least 1 day before for preparations of necessary documents. Provided total fee has been paid, payment will be credited towards the rescheduled
dates or to a future program should there be no substitution. No refunds are available for cancellations or postponements. COMFORI SDN. BHD. reserves
the right to cancel or postpone the program due to unforeseen circumstances. COMFORI SDN. BHD. reserves the right to modify or alter the advertised topics
if necessary. Certificate of Attendance will be given only after payment is received. Clients who will pay after the event due to late registrations will be required
to submit a Letter of Undertaking as a payment guarantee.


FE011-Earthing and Protection Systems 12&13 Apr 2011.pdf - page 1/4
FE011-Earthing and Protection Systems 12&13 Apr 2011.pdf - page 2/4
FE011-Earthing and Protection Systems 12&13 Apr 2011.pdf - page 3/4
FE011-Earthing and Protection Systems 12&13 Apr 2011.pdf - page 4/4

Related documents


fe011 earthing and protection systems 12 13 apr 2011
eb mission critical earthing 22 23dec
eb mission critical earthing 15 16nov free 1
earthing and protection system
earthing bonding 2012
fe010 power systems protection for engineers ka


Related keywords