CYME NEPLAN SINCAL DIGSILENT PSSE ETAP (PDF)




File information


Title: Microsoft PowerPoint - CYME-NEPLAN-SINCAL-DIGSILENT-PSSE-ETAP.08.28.2013

This PDF 1.5 document has been generated by PScript5.dll Version 5.2.2 / Acrobat Distiller 11.0 (Windows), and has been sent on pdf-archive.com on 18/05/2014 at 15:58, from IP address 93.115.x.x. The current document download page has been viewed 2302 times.
File size: 550.35 KB (38 pages).
Privacy: public file
















File preview


Comparing Features of 
CYME/SINCAL/NEPLAN/PSSE/DIgSIL
ENT/ ETAP
Modeling/Modules/Database/estimation / 
Features/Facilities

1

Equipment's Modeling

2

Equipment

CYME

SINCAL

NEPLAN

PSS/E

DIgSILENT

ETAP













Individual PI Modeling for 
harmonic analysis







-





Distributed Model for 
fundamental frequency , 
considering G



-







-

Distributed Transposed & 
distributed transposed with skin 
effect  model for harmonic 
analysis



-



-



-













equivalent Impedance % for 
fundamental frequency analysis













Detail Modeling of upstream 
substation in fundamental
frequency analysis



-

-

-

-

-

Model as equivalent impedance 
% for harmonic orders







-





CABLE
PI Model in Fundamental 
frequency, Considering R , X & B
(phase & sequence),

Power Grid (Network Equivalent )

3

Equipment

CYME

SINCAL

NEPLAN

PSS/E

DIgSILENT

ETAP





-

-

-

-

-





-

-

-

Two winding Transformer,













Z% and X/R(positive/zero)
Star , Delta, Shell type, No 
Load Losses













Open delta



-

-

-

-



Zigzag











-

User defined Equivalent 
harmonic impedance 
modeling for each harmonic 
order according to harmonic 
frequency scan of upstream 
source 
Exponential Function for 
harmonic modeling

4

Equipment

CYME

SINCAL

NEPLAN

PSS/E

DIgSILENT

ETAP



-





-

-

Grounding Transformer





-

-

-

-

Regulator, star, delta, open 
phase

√√





-

√√

-

Two winding Auto transformer



-



-

-

-

Three winding transformer













Z% and X/R(positive/zero)
Star , Delta, Shell type, No 
Load Losses





-







Zigzag











-

-



-

-

-

Core type, Y0/DO

Three winding Auto 
transformer



5

Equipment

CYME

SINCAL

NEPLAN

PSS/E

DIgSILENT

ETAP













(Balance /PI Modeling for 
fundamental frequency, 
Considering R , X & B
(phase & sequence),













Single circuit Over head line, 
considering G , distributed
model for fundamental 
frequency









-

Individual PI Modeling for 
harmonic analysis
Series R‐L, PI model, for 
harmonic analysis







-





Distributed Transposed for 
harmonic analysis



-



-



-

distributed transposed with skin 
effect , distributed transposed 
frequency dependent, 
distributed untransposed for
harmonic analysis



-



-



-

Single circuit Over head line

-

6

Equipment

CYME

SINCAL

NEPLAN

PSS/E

DIgSILENT

ETAP

By phase, Single phase







-





Unbalance, Transposed, 
untransposed



-



-

-

-













Balance /PI Modeling for 
fundamental frequency, 
Considering R , X & B
(phase & sequence),













considering G , distributed
model for fundamental 
frequency



-







-

Individual PI Modeling for 
harmonic analysis, Series R‐L, 
PI model, for harmonic analysis







-





Double circuit Overhead line

7

Equipment

CYME

SINCAL

NEPLAN

PSS/E

DIgSILENT

ETAP

Distributed Transposed for 
harmonic analysis



-

-

-



-

distributed transposed with skin 
effect , distributed transposed 
frequency dependent, distributed 
untransposed for harmonic 
analysis



-

-

-

-

-

Series Reactor
Inductive Reactance, Ohm/per 
phase, Sequence, 













4 winding Transformer

-

-



-

-

-

Series Capacitor, B, R

√√





-



-

Shunt reactor, reactive power, KW 
Losses, Loss Factor

√√

-



-

√√

-

Shunt capacitor, reactive power, KW 
Losses, Loss Factor

√√

√√

√√

√√

√√



Switchable Shunt reactor/capacitor











-

Grounding transformer



-

-

-



-

8

Equipment

CYME

SINCAL

NEPLAN

PSS/E

DIgSILENT

ETAP

Bus way‐Busduct, Z%, X/R 
(positive, zero sequence), length



-



-



-

Induction Motor













Dynamic Model, based on 
constant Equivalent circuit 
parameters













Frequency dependent Dynamic 
Model/ Applying skin effect for 
starting mode, considering cage 
factor

√√

-

-

-



-

Motor Starting /  considering 
transition scheme as opened and
closed



-

-

-

-

-

Motor starting devices, Direct, 
YD+Zstartor, Auto transformer, R 
rotor, Current limit

√√

√√

√√

-

-

√√

VFD AS starter, voltage and current 
Soft starter, Capacitor assistance, 
Motor starting curve

√√

-

-

-





Phase shifting transformer
Active power control mode

√√

√√



-



9






Download CYME-NEPLAN-SINCAL-DIGSILENT-PSSE-ETAP



CYME-NEPLAN-SINCAL-DIGSILENT-PSSE-ETAP.pdf (PDF, 550.35 KB)


Download PDF







Share this file on social networks



     





Link to this page



Permanent link

Use the permanent link to the download page to share your document on Facebook, Twitter, LinkedIn, or directly with a contact by e-Mail, Messenger, Whatsapp, Line..




Short link

Use the short link to share your document on Twitter or by text message (SMS)




HTML Code

Copy the following HTML code to share your document on a Website or Blog




QR Code to this page


QR Code link to PDF file CYME-NEPLAN-SINCAL-DIGSILENT-PSSE-ETAP.pdf






This file has been shared publicly by a user of PDF Archive.
Document ID: 0000163650.
Report illicit content