PDF Archive

Easily share your PDF documents with your contacts, on the Web and Social Networks.

Share a file Manage my documents Convert Recover PDF Search Help Contact



MSDS # B8302 # JZ 201402100003.PDF


Preview of PDF document msds-b8302-jz-201402100003.pdf

Page 1 2 3 4 5 6 7

Text preview


深 圳 市 金 卓 电 源 科 技 有 限 公 司
Shenzhen

Page 3 of 7

JinZhuo Power Science & Technology Co., Ltd

S26
S36
S 45

In case of contact with eyes, rinse immediately with plenty of water and seek medical attention.
Wear suitable gloves.
In case of incident, seek medical attention

4-

FIRST AID MEASURES

In case of battery rupture or explosion, evacuate personnel from contaminated area and provide maximum
ventilation to clean out fumes/gases.
In all cases, seek medical attention.
Eye contact:
Skin contact:

Flush with plenty of water (eyelids held open) for at least 15 minutes.
Remove all contaminated clothing and flush affected areas with plenty of
Water and soap for at least 15 minutes
Do not apply greases or ointments.

Ingestion:

Dilute by giving plenty of water and get immediate medical attention.
Assure that the victim does not aspirate vomited material by use of positional drainage.
Assure that mucus does not obstruct the airway.
Do not give anything by mouth to an unconscious person.

Inhalation:

Remove to fresh air and ventilate he contaminated area.
Give oxygen or artificial respiration if needed.

5–

FIRE-FIGHTING MEASURES

Fire and exposion hazard:

The batteries can leak and/or spout vaporized or decomposed and
combustible electrolyte fumes in case of exposure above 80 C
resulting from inappropriate use, abuse, or from the environment.
Possible formation of hydrogen fluoride (HF) and

phosphorous oxides
during fire. LiPF6 salt contained in the electrolyte releases hydrogen
fluoride (HF) in contact with water.
Extinguishing media:

Suitable:………Type D extinguishers, Co2, Dry chemical or Foam extinguishers
Not to be used: ……

Special exposure hazards:
Eye contact:
Skin contact:
Ingestion:
Inhalation:
Special protective equipment:

Address:

Spray or immerse in water

Following cell overheating due to external source or due to improper
use, electrolyte leakage or battery container rupture may occur and
release inner component/material in the environment.
The electrolyte solution contained in the battery is irritant to ocular
tissues.
The electrolyte solution contained in the battery causes skin irritation.
The ingestion of electrolyte solution causes tissue damage to
throat and gastro/respiratory tract.
Contents of a leaking or ruptures battery can cause respiratory tract,
mucus, membrane irritation and edema.
Use self-contained breathing apparatus to avoid breathing irritant
fumes.
Wear protective clothing and equipment to prevent body contact with
electrolyte solution.

Unit C, Longhu Industrial Zone, Shahu,
Pingshan New District, Shenzhen
Guangdong ,PRC

Tel:86-755-84513533
Fax:86-755-84513233
http://www.jinzhuopower.com