A
B
C
D
1
1
2
2
Hi-limit Sensor
Temp Sensor
75 degF
75 degF
51K
24K
94 degF
115 degF
J1
33K
1
2
3
4
5
6
7
8
9
10
11
12
13
14
33K
3
No Flow
Flow Sensor
Good Flow
Interlock Jumper
3
J6 sensor connector - back side
4
33K = approx 75 degF
33K || 51K = 20K = approx 94 degF
33K || 24K = 14K = approx 115 degF
13 11
7
14
8
3
1
4
2
4
5
5
OPTIMA 850 LCD
Sensor Test Cable
A
B
C
D
Created with novaPDF Printer (www.novaPDF.com). Please register to remove this message.