Combined Temperature/
Humidity Sensor
in shelter
3031.0000 BG
Page: 1 / 4
3
2
1
Issue.
12.09
10.09
07.09
Zi
Zi
Date
Name
Technical Data
Material of probe:
ABS-plastic
Cable:
(Versions 3031.0000 and
.1000 only)
LiY( C )Y, 11 x 0.25 mm2,
length 3 m
(fan: LiYY, 2 x 0.25 mm2,
length 3 m)
Power consumption:
approx. 3.0 mA at
12 V DC (Versions
3031.0000)
Fan:
12 V DC, approx. 70 mA
(Versions 3031.1000
and .1200 only)
Humidity sensor:
Meas. range:
Calibrating accuracy:
Max. annual drift:
Time constant:
Output:
Capacitive element
0...100 % rH
±1 % rH
1 % rH / year
0.7 s
0...1 V corresp.
0...100 % rH
> 10 kΩ
Impedance:
Temperature sensor:
Output 1:
Output 2:
Description
The transmitter type 3031 is designed for measurement of relative humidity and temperature. Sensing is
accomplished by capacitive measuring element for
humidity and a platinum resistor Pt 100 for temperature measurement. Both sensors are located at the
tip of a probe and protected by a membrane filter.
The probe is mounted at the base plate by means of
a special socket. There the probe is fixed with a fixation screw. The base plate provides 2 holes, 30 mm
distance, for M8 screws for fastening.
The unit is protected by a radiation protection shelter,
made of a special white plastic material.
Following versions are further available:
Version with electrical ventilation, to obtain exact
measuring values even with total calm.
Version with measuring converter which is placed in
a housing underneath the sensor. Data output is
4...20 mA each.
Pt 100, according to
DIN 60751 B, 1/3 tolerance
Measuring resistance
Pt 100, 4 line
0…1 V accordingly
-40…+60 °C
Compliances:
Power supply:
WMO Guide No. 8/7th ed.
5...24 V DC; < 4 mA
(without fan and electrical
ventilation)
Operating temp.:
-40...+85 °C
Dimensions (shelter):
∅ 130 mm,
height approx. 185 mm
Weight
(shelter with holder):
Measuring converter:
Input:
approx. 780 g
Voltage: 0...1.0 V;
meas. range: 0...100 %
Pt 100, meas. range
–35...+45 °C
Output:
4...20 mA; supply 18...30 V
DC, load depending
(500 Ω...1.9 kΩ lin.)
Max. error:
±0.25 %
Error by:
Supply voltage: <50 ppm/V
Ambient temp.: <50 ppm/°C
EMV, Emission:
EN 50081-1
EMV, Noise:
EN 50082-2
Connection:
8-p. connector, IP 67
sealed (plugged)
3031.0000 BG
Combined Temperature/
Humidity Sensor in shelter
Ordering Code
Page: 2 / 4
Calibration and Maintenance
Temperature/humidity sensor, in shelter
3031.0000
Temperature/humidity sensor, in shelter, electrically aspirated
3031.1000
Temperature/ humidity sensor incl.
measuring converter 4...20 mA, in
shelter
3031.0200
Temperature/ humidity sensor incl.
measuring converter 4...20 mA, in
shelter, electrically aspirated
3031.1200
Calibration and maintenance of the probe should be
performed at regular intervals, at least once a year or
more often, depending on the conditions of use and
desired accuracy.
Replacing of Sensor
Loosen fixation screw. Pull sensor out of its socket
and replace it by a new one. Sensor has to be
touched carefully, at its plastic shaft.
Connection plan
Versions 3031.0000 and 3031.1000
0,25 mm²
weiß /
white
Pt 100
braun / brown
Pt 100
grün /
green
Pt 100
gelb /
yellow
Pt 100
grau /
grey
rot /
red
Versorgungsspannung
Supply voltage
Ausgang r.F.
Output r.H.
Ausgang °C
Output °C
DIO
Pt 100
Kabel
Cabel
orange / orange
blau /
blue
violett / purpel
DIO
schwarz (schrumpf)
black (shrunk)
schwarz
black
Analog Masse
analogue ground
Digital Masse und Power
digital ground and power
0,25 mm²
Kabel
Cabel
+
weiß / white
12 VDC für Lüfter
12 V DC for fan
-
braun / brown
DIO = Digital Input / output;
used for calibration purpose, only, not used for normal operation!
3031.0000 BG
Combined Temperature/
Humidity Sensor in shelter
Page: 3 / 4
Versions 3031.0200 and 3031.1200; 4…20 mA
+U1
1 ws / white
+U3
3 gr / grey
+U2
2 br / brown
ws / white
gr / grey
V+
1
gn / green
3
ge / yellow
Feuchte
Sensor
Humidity
sensor
Messumformer
Temp.
Pt 100
bn / brown
ws / white
5
4
R L +I2
-U3
R +I1
-U2
-U1
Pin configuration:
ws/white
br/brown
gn/green
ge/yellow
gr/grey
rs/pink
L
1
2
3
4
5
6
+U1
+U2
+U3
+ I1
+ I2
- U3
rt / red
UA
GND
sw / black
Meas.
converter
Temp.
Externe Beschaltung
External circuitry
1
Schirm / shield
+ 3 Messumformer
Feuchte
-
4
Meas.
converter
Humidity
2
2
gn / green
ge / yellow
5 gn / green
6 sw / black
4 ge / yellow
(Supply meas. conv. humidity)
(Supply meas. conv. temp.)
(Supply humidity sensor)
(4...20 mA humidity)
(4...20 mA temp.)
(AGND humidity sensor)
+I1/+I2 measured against -U1/-U2
U1, U2 = 18...30 V DC (admissible load!).
U3
= 3,5...50 V DC (admissible load!).
Attention:
Power supply U1, U2 must be electrically
isolated from U3!
Cable Connector
2
2
8
1
6
4
5
5
4
3
7
Front side, female
socket
8
3
7
1
6
View on the solder termination side
3031.0000 BG
Combined Temperature/
Humidity Sensor in shelter
Page: 4 / 4
Dimensions for installation:
Top shield plate
Mounting special socket, M4
Thread rod, M5
Hole for fan cable
30
ø 8,5
ø 8,5
99
25
Technical data are subject to change!
THEODOR FRIEDRICHS & CO.
Meteorologische Geräte und Systeme GmbH
POB 1105 • D 22858 Schenefeld • Tel. (040) 839 600-0 • Fax (040) 839 600-18
Email: info@th-friedrichs.de • http://www.th-friedrichs.de




Link to this page
Permanent link
Use the permanent link to the download page to share your document on Facebook, Twitter, LinkedIn, or directly with a contact by e-Mail, Messenger, Whatsapp, Line..
Short link
Use the short link to share your document on Twitter or by text message (SMS)
HTML Code
Copy the following HTML code to share your document on a Website or Blog