3032.0000.pdf

Text preview
3032.0000 BG
Page 2 / 7
Humidity sensor
Capacitive element
Meas. range:
0...100 % rH
Meas. accuracy:
10…90 % rH at 23 °C
<10 % rH >90 % rH
1.5 %
2 %
Temp. influence TK (# 23 °C):
<0.05 % rH/K
Calibrating accuracy:
1 % rH
max. annual drift:
1 % rH / year
Time constant:
0.7 s
output:
0...1 V corresp. 0...100 % rH
impedance:
> 10 k
Response time:
T63:
T90:
typical 10 s
approx. 20 s
Temperature sensor
Output
Measuring resistance Pt 100, 4 line
Pt 100, according to DIN 60751 B, 1/3 tolerance
Meas. element (acc. DIN IEC 751):
Pt 100 1/3-DIN class B
Accuracy at 23 °C (activated output):
±0.2 K
Temp. influence TK (# 23 °C)
(activated output):
<0.005 K/K
Response time:
T63:
T90:
typical 4 s
approx. 8 s
General
Compliances:
WMO Guide No. 8/7th ed.
Power supply:
5...30 V DC; 4 mA (without fan and electrical ventilation)
Operating temp.:
-40...+85 °C
min. wind speed at sensor head:
0.5 m/s
Protection, probe:
IP65
Protection, connector:
IP67
Power requirement 0…10 V/0…1 V:
<3 mA
Load resistance
0…10 V/0…1 V:
10k / 2k
EMC according:
EN 61326-2-3
Dimensions (shelter):
130 mm, height approx. 185 mm
Weight (shelter with holder):
approx. 780 g