Hybrid Surge Protection DC DC converter(HSTR28S Series)
1 Features of surge protection DC DC converter


High reliability



Wide input voltage range:15V~50V,Nominal
DC input voltage: 28V



Surge protection voltage:80V,1s

Dimensions: 54.40×29.00×10.66mm
(without flange)



Output Power PO:40W



Operating temperature range Tc:-55℃~+125℃



Low Startup current



No output overshoot



Inhibit function

HSTR28S3R3 H

HSTR28S8



Input under-voltage locked function

STR28S3R3F

HSTR28S8F

and output short circuit protection

HSTR28S5

HSTR28S12



Maximum power density:41W/in3

HSTR28S5F

HSTR28S12F



Hermetically sealed metal case

HSTR28S5R2

HSTR28S15

HSTR28S5R2F

HSTR28S15F

Dimensions:74.00×29.00×10.66mm (with flange)

Weight:47g(without flange)
55g (with flange)

Table 1 Device models

2 Scope of application of surge protection D
C DC converter

High-reliability electronic system for aviation and aerospace, etc

3 Description of surge protection DC DC converter
This series device is highly reliable and is featured with surge protection (80v, 1s) for surge protection
DC DC converter. Single ended, pulse width modulated and transformer magnetic feedback topology
design is used in this device. The operating principle is that the sampling signal of output voltage, coupled
by the opto-coupler, works together with the sampling signal of input loop current to regulate the pulse
width of the controller. The double loop control creates constant voltage output and short circuit protection.
Devices are produced by using thick film hybrid integration process, and metal package seali
ng. The design and manufacturing process of HTR 28 Series of converters are in compliance with
General Standards of Hybrid Integrated Circuits and detailed specification of manufacturing. Input
terminal connected to the accessory power supply filter can improve the electro-magnetic compati
bility of devices.

4 Technical Specifications of surge protection DC DC converter
Table
Absolute Max. Rating

2

Rated conditions and recommended operating conditions

Web :www.ecrimpower.com E-mail: sales@ecrim.cn

Phone: +86 551-63667943 Fax: +86 551-65743191

-1-

Input voltage:15V~50V
Input voltage(Transient,1s):80V
Output Power:41.5W
Storage temperature:-65℃~150℃

Mechanical Shock:1500g
Lead resistance welding temperature:300℃(15s)
Weight(without flange/ with flange):47g/55g
Antistatic intensity:2000V

Table 3 (a)
No.
1
2
3
4
5
6
7
8
9

Items
Input Voltage/V
Output
Voltage/V
Output current/A
Output Power/W
Output Ripple
Voltage/mV
Line
Regulation/mV
Load
Regulation/mV
Input
current/mA
Input Ripple
current/mA

10

Efficiency/%

11

Isolation/MΩ

12

Inhibit Function
Inhibit
open-circuit
Voltage/V
Under voltage
open voltage/V
Under voltage
cut-off voltage/V
Short Circuit
Protection

13
14
15
16
17

Capacitive load
/μF

18

Switching
frequency/kHz

19

External
Synchro
Frequency
Range/kHz

20
21

Step Load
Response
Transient(mV
pK)
Step Load
Response

Electrical characteristics
HSTR28S3R3
HSTR28S3R3F

HSTR28S5R2
HSTR28S5R2F

Min

Max

Min

Max

Min

Max

15

50

15

50

15

50

3.25
3.20

0

3.35
3.40
6.06
20

5.14
5.07

0

5.26
5.33
6
31

7.92
7.88

0

8.08
8.12
4.4
35



50



50



50



20



20



20

Io=No load to load



50



50



50

Inhibit
Io=no load
BW=20MHz,Io=Full
load
Io=Full
load
Input to output or any
pin to case(except pin
7、8)at 500V,TA=25℃




6
60




6
60




6
60



50



50



50

65



72



74



100



100



100



0

0.7

0

0.7

0

0.7

9

13

10

14

10

14

12

14.8

12

14.8

12

14.8

11

14.5

11

14.5

11

14.5

Conditions
Low、High、Ambient
Temperature
Ambient
Io=Full
Load
Low/high
VIN=15V~50V
BW=6MHz,Io=Full
load
VIN=15V~50V,
Io=Full

Io=Full
Load
Io=Full
Load
Io=Full
Load

Reduced flow pattern
Tc=25℃

Reduced flow
pattern

HSTR28S8
HSTR28S8F

Reduced flow pattern



1000



1000



500

400

550

400

550

400

550

400

550

400

550

400

550

50%load→full load
→50%load

-500

500

-500

500

-500

500

50%load→full load
→50%load



500



500



500

Io=Full
Load
TC=25℃,full load,
TTL electrical level
(VIH≥4.5V,
VIL≤0.8V),Duty Ratio
40%~60%

Web :www.ecrimpower.com E-mail: sales@ecrim.cn

Phone: +86 551-63667943 Fax: +86 551-65743191

-2-

22

23
24
25

Recovery(μs)
Step Line
Response
Transient(mV
pK)
Step Line
Response
Recovery(μs)
Start-up
Overshoot(mV
pK)
Start-up Delay
(ms)

VIN:16V→40V,
VIN:40V→16V,
Io=Full load

-600

600

-600

600

-600

600

VIN:16V→40V
VIN:40V→16V
Io=Full load



500



500



500

VIN:0→28V,
Io=Full load



15



50



50

VIN:0→28V,
Io=Full load



20



20



20

Table3 (b) Electrical characteristics

No.

Parameter

1

Input Voltage/V

2

Output Voltage/V

3
4

Output current/A
Output Power/W
Output Ripple
Voltage/mV
Line
Regulation/mV
Lode
Regulation/mV

5
6
7
8

Input current/mA

9

Input Ripple
current/mA

10

Efficiency/%

11

Isolation/MΩ

12

Inhibit Function
Inhibit open-circuit
Voltage/V
Under-voltage open
voltage/V
Under-voltage
cut-off voltage/V
Short Circuit
Protection

13
14
15
16
17
18

Capacitive load
/μF
Step Load
Response
Transient(mV pK)

HSTR28S5
HSTR28S5F

Conditions

HSTR28S12
HSTR28S12F

HSTR28S15
HSTR28S15F

Min

Max

Min

Max

Min

Max

15

50

15

50

15

50

4.95
4.88

0

5.05
5.12
6
30

11.88
11.70

0

12.12
12.30
3.33
40

14.85
14.62

0

15.15
15.38
2.67
40



50



50



50

VIN=15V~50V,Io=Full



20



20



20

Io=No load to load



50



50



50

Inhibit
Io=no load
BW=20MHz,Io=Full
load
Io=Full
load
Input to output or any pin to
case(except pin 7、8) at
500V,TA=25℃




6
60




6
60




6
60



50



50



50

72



76



77



100



100



100



0

0.7

0

0.7

0

0.7

10

14

10

14

10

14

12

14.8

12

14.8

12

14.8

11

14.5

11

14.5

11

14.5

Low、High、Ambient
Temperature
Ambient
Io=Full
Load
Low/high
VIN=15V~50V
BW=6MHz,Io=Full
load

Io=Full
Load
Io=Full
Load
Io=Full
Load

Reduced flow
pattern

Reduced flow
pattern

Reduced flow
pattern

TA=25℃



1000



500



500

50%load→full load
→50%load

400

550

400

550

400

550

Web :www.ecrimpower.com E-mail: sales@ecrim.cn

Phone: +86 551-63667943 Fax: +86 551-65743191

-3-

19

External Synchro
frequency
range/kHz

Tc=25℃,full load,TTL
electrical level(VIH≥4.5V,
VIL≤0.8V)
,Duty Ratio
40%~60%

400

550

400

550

400

500

20

Step Load
Response
Recovery(μs)

50%load→full load
→50%load

-500

500

-700

700

-700

700

21

Step Line Response
Transient(mV pK)



500



500



500

22

Step Line Response
Recovery(μs)

-600

600

-900

900

-900

900

23

Start-up Overshoot
(mV pK)



500



500



500

24

Start-up Delay (ms)



50



50



50

25

Step Load
Response
Transient(mV pK)



20



20



20

VIN:16V→40V,
VIN:40V→16V,Io=Full
load
VIN:16V→40V
VIN:40V→16V
Io=Full load
VIN:0→28V,
Io=Full load
VIN:0→28V,
Io=Full load
50%load→full load
→50%load

5 Circuit block diagram of surge protection DC DC converter

Fig. 1

HSTR28S Series circuit block diagram

6. Typical Characteristic Curve of surge protection DC DC converter
(Unless otherwise specified, test conditions for the following curves in Fig2- Fig.5 are
Tc=25℃,VIN=28V±5%,)

Web :www.ecrimpower.com E-mail: sales@ecrim.cn

Phone: +86 551-63667943 Fax: +86 551-65743191

-4-

Fig. 2

Fig. 3

HSTR28S15 Efficiency

HSTR28S15

Web :www.ecrimpower.com E-mail: sales@ecrim.cn

Input Step Line Response

Phone: +86 551-63667943 Fax: +86 551-65743191

-5-

Fig. 4

Fig. 5

HSTR28S15 Step Load Response

HSTR28S15 Start-up Overshoot/Start-up Delay

7.MTBF Curve of surge protection DC DC converter

Fig. 6

MTBF Temperature Curve(HSTR28S15)

8 Pin Designation of surge protection DC DC converter

Web :www.ecrimpower.com E-mail: sales@ecrim.cn

Phone: +86 551-63667943 Fax: +86 551-65743191

-6-

Fig. 7

Pin

Pin Out Bottom View

Table 4

Pin Designation
Symbol

Designation

1

VI

Positive Input

2

INH

Inhibit

3

Sense-

Sensitive Negative Output

4

GNDO

Output Ground

5

VO

Positive Output

6

Sense+

Sensitive Positive Output

7

GNDC

Case Ground

8

GNDC

Case Ground

9

SYN

External Synchro Input

10

GNDI

Input Ground

9 Typical Connection Diagram of surge protection DC DC converter

Fig. 8

Web :www.ecrimpower.com E-mail: sales@ecrim.cn

Connection Diagram

Phone: +86 551-63667943 Fax: +86 551-65743191

-7-

Fig. 9

EMI Filter Connection Diagram

Fig. 10 Inhibit Driver Circuit Diagram

10.Package Outline Dimensions of surge protection DC DC converter (Unit:
mm)
① Package without flange

Fig. 11 Bottom View
Web :www.ecrimpower.com E-mail: sales@ecrim.cn

Fig. 12 Side View
Phone: +86 551-63667943 Fax: +86 551-65743191

-8-

② Package with Flange

Fig. 13

Bottom View

Fig. 14

Table 5
Symbol

Package Outline
Unit/mm
Typical

Min

A
Φb
D
e
e1
E
L
ΦP
X
X1


0.87




5.40
3.80

64.27

Table 6
Case Model

Header

UPP5429-10j

Cold Rolled

(without flange) Steel(10#)
UPP5429-10n

Cold Rolled

(with flange)

Steel(10#)

Header
Plating
Ni

Ni

Cover
Kovar
(4J42)
Kovar
(4J42)

Side View

Max


1.00

10.16
20.32


4.10

64.77

10.66
1.13
54.40


29.0

4.40
74.00
65.27

Case Materials
Cover
Plating
Ni

Ni

Pin
Cu –core
Compound
Cu
Compound

Pin

Seal

Plating

Notes
Ni Plating is

Ni/Au

Parallel seam

for case
ground pin
Ni Plating is

Ni/Au

Parallel seam

for case
ground pin

11 Ordering Information of surge protection DC DC converter

Web :www.ecrimpower.com E-mail: sales@ecrim.cn

Phone: +86 551-63667943 Fax: +86 551-65743191

-9-


Related documents


hsdf28d 20w
hstr28s 40w
hstr28d 40w
hssa28d 6w
hntf5s
hntf5s


Related keywords