HIOKI 3291-50 ENG 100%

Cuts high-harmonic components to measure the fundamental waveform (The filter in the 3293-50 is enabled by default.) Auto range 3293-50 3 Filter out noise 600.0A 1000A 600.0A 1000A Auto range 60.00A Range Filter on 4 Includes a Peak Hold function Captures the peak value of fluctuating currents.

https://www.pdf-archive.com/2015/12/24/hioki-3291-50-eng/

24/12/2015 www.pdf-archive.com

HIOKI 3281 ENG 94%

DIGITAL CLAMP ON HiTESTER 3282 (1000A AC, ø46mm max.) 3281 (600 A AC, ø33mm max.) Field measuring instruments Beats distorted waveform to y s a E p!

https://www.pdf-archive.com/2015/12/24/hioki-3281-eng/

24/12/2015 www.pdf-archive.com

HIOKI 3390 ENG 72%

o Measure the primary and secondary sides of inverters o Advanced motor analysis functions o Measure inverter noise V A kW Large Assortment of Wide-band, High-Precision Feed-Through Current Sensors 4 Models 50A 200A 500A 1000A Effect of conductor position Effect of external electromagnetic field Completely Minimized CT6862 CT6863 9709 CT6865 2 Current Sensor Method Surpasses the Accuracy of Direct Connection Method Power Analyzer 3390 When combined with the feed-through current sensors Maximum accuracy of ±0.16% ±0.1% ±0.06% Clamp-on sensors Feed-through current sensors AC/DC 9709 AC/DC CT6862 AC/DC CT6841 AC 9272-10 Current sensor design allows for safe and efficient testing For Current Sensor specifications, please go to • Choice of sensors include easy-to-measure AC and AC/DC clamp-on sensors and feed-through current sensors for highaccuracy measurements • Immune to in-phase noise effects when measuring inverters page 15 Power Analyzing Control Engine Technology processes Weight &

https://www.pdf-archive.com/2015/12/24/hioki-3390-eng/

24/12/2015 www.pdf-archive.com

HIOKI 3193-10 ENG 60%

AC/DC CURRENT SENSOR ■ Rated at 1000A rms ■ Wide bandwidth ■ Super high precision 2 Broad coverage, high accuracy, and well-developed interface Complete with functions that answer all your power measurement needs.

https://www.pdf-archive.com/2015/12/24/hioki-3193-10-eng/

24/12/2015 www.pdf-archive.com

HIOKI 3287 ENG 57%

AC/DC Multi-Function Clamp 3288 AC/DC 1000A max.

https://www.pdf-archive.com/2015/12/24/hioki-3287-eng/

24/12/2015 www.pdf-archive.com

HIOKI PW6001 ENG 50%

Choose from a diverse array of sensors to cover very small currents from 10mA up to large 1000A loads.

https://www.pdf-archive.com/2015/12/25/hioki-pw6001-eng/

25/12/2015 www.pdf-archive.com

HIOKI LR8400-92 ENG 46%

IR4018-20 FAIL (Red) When the measured value is less than the reference value Earth HiTester 3151 AC 600V 3 Electrode method 500V/100MΩ 500V/1000MΩ 1000V/2000MΩ 250V/100MΩ, 500V/100MΩ, 1000V/4000MΩ Luminous Scale Continuous beep 3-electrode measurement provides greater precision Analog MΩ HiTester IR401X-20, 3490 250 to 1000V single- or 3-range PASS (No change) When the measured value is greater than or equal to the reference value Short beep IR4057-20 Choose a single-, or 3-range model depending on your application AC/DC 600V 0 to 1150Ω • Wide measurement range for 0 to 1150 Ω, based on EN standard • Switchable measurement frequency to minimize the influence of harmonic earth voltage • Semi-dust-proof construction Bright LED (option) Clamp testers for AC/DC current and voltage measurement High-accuracy voltage measurement No metal contact phase detection Clamp On AC/DC HiTester 3288-20, 3285 Digital Multimeter DT4282 Phase Detector 3129-10 True RMS True RMS True RMS φ35mm φ55mm AC/DC 1000V AC/DC 1000A AC/DC 2000A AC/DC 10A • Compact &

https://www.pdf-archive.com/2015/12/25/hioki-lr8400-92-eng/

25/12/2015 www.pdf-archive.com

HIOKI 3286 ENG 41%

1 A to 1000A, Power:

https://www.pdf-archive.com/2015/12/24/hioki-3286-eng/

24/12/2015 www.pdf-archive.com

Higher alcohols YRTPH 2102 25%

/ Regulatory Toxicology and Pharmacology 50 (2008) 313–321 Table 2 NOAEL for alcohols estimated from 1-butanol and isoamyl alcohol using the relative acute toxicities Alcohol NOAEL (mg/kg/day) calculated from 1-butanol NOAEL (mg/kg/day) calculated from isoamyl alcohol Methanol Ethanolb 1-Propanol 1-Butanol 2-Butanol Isobutanol Isoamyl alcohol 1-Hexanol 891 (1117) 296 125a 347 389 206 114 4329 (5431) 1438 608 1687 1892 1000a 554 317 Of course, these concentrations must be read as preliminary in light of several methodological limitations to our study.

https://www.pdf-archive.com/2014/11/14/higher-alcohols-yrtph-2102/