Search


PDF Archive search engine
Last database update: 21 April at 11:28 - Around 76000 files indexed.


Show results per page

Results for «airflow»:


Total: 37 results - 0.037 seconds

PRESENTATION 100%

δ = 60° δ Separation of the airflow occurs:

https://www.pdf-archive.com/2013/06/18/presentation/

18/06/2013 www.pdf-archive.com

PRESENTATION v2 100%

speed 228 km/h Acceleration 0-100 km/h 8.10 s Fuel consumption 4.9 l/100km CO2 emission 131 g/km FRONT PROFILE  α = 8.5°  β = 18°  δ = 60° Separation of the airflow occurs:

https://www.pdf-archive.com/2013/06/23/presentation-v2/

23/06/2013 www.pdf-archive.com

AERODYNAMICS PRESENTATION 100%

speed 228 km/h Acceleration 0-100 km/h 8.10 s Fuel consumption 4.9 l/100km CO2 emission 131 g/km FRONT PROFILE  α = 8.5°  β = 18°  δ = 60° Separation of the airflow occurs:

https://www.pdf-archive.com/2013/06/26/aerodynamics-presentation/

26/06/2013 www.pdf-archive.com

Untitled Document 95%

660 Height (mm) 290 (695) Height (inch) 11-7/16 (27-3/8) Width (mm) 1,070 (875) Width (inch) 42-5/32 (34-15/32) Depth (mm) 240 (320) Moisture Removal Air Circulation (Indoor/Hi) Dimensions 1/3 3/26/2018 Net Weight Refrigerant Pipe Diameter Pipe Extension Depth (inch) 9-15/32 (12-5/8) kg 12 (52) lb 26 (115) Liquid Side (mm) ø 6.35 Liquid Side (inch) 1/4 Gas Side (mm) ø 15.88 Gas Side (inch) 5/8 Chargeless Pipe Length (m) 7.5 Maximum Pipe Length (m) 25 Maximum Elevation Length (m) 20 Additional Refrigerant Gas* (g/m) 30 Power Supply Comfort Cleaner Air Indoor iAUTO-X No iAUTO Yes ECONAVI No Temperature Wave No AUTOCOMFORT No Inverter Control No Quiet Mode No Soft Dry Operation Mode Yes Personal Airflow Creation No Airflow Direction Control (Up Down) Yes Manual Horizontal Airflow Direction Control Yes Automatic Operation Mode (Cooling) Yes nanoe-G No 2/3 3/26/2018 Convenience Reliability NOTE Odour-Removing Function Yes Removable, Washable Panel Yes 24-Hour Dual ON OFF Real Setting Timer No 24-Hour ON OFF Real Setting Timer Yes LCD Wireless Remote Control Yes Wired Remote Control No Random Auto Restart (32 Restart Patterns) Yes Blue Fin Condenser Yes Long Piping (Numbers indicate the maximum pipe length) 25m Top-Panel Maintenance Access Yes Self-Diagnostic Function No * When pipes are not extended from the standard pipe length, the required amount of refrigerant is already in the unit.

https://www.pdf-archive.com/2018/03/26/untitled-document/

26/03/2018 www.pdf-archive.com

AE 80 Sub 81%

Air delivery shall be no less than the airflow values and no greater than the sound level values listed in the HVI Performance Specifications provided in this specification (see following chart).

https://www.pdf-archive.com/2016/11/09/ae-80-sub/

09/11/2016 www.pdf-archive.com

IEEF Publications 79%

Zhiqiang (John) Zhai Abstract Computational fluid dynamics (CFD), as the most sophisticated airflow model, can simultaneously predict airflow, heat transfer and contaminant transportation in and around buildings.

https://www.pdf-archive.com/2014/01/28/ieef-publications/

28/01/2014 www.pdf-archive.com

Tours in Jaco (1) 75%

The design offers a very welcoming cooling airflow across the command bridge and the “express boat” designed has lots of seating under the shaded canopy.

https://www.pdf-archive.com/2016/02/12/tours-in-jaco-1/

12/02/2016 www.pdf-archive.com

Info kit N260GTX-T2D896-OC 67%

Blow direct airflow to cool down 2.

https://www.pdf-archive.com/2017/10/30/info-kit-n260gtx-t2d896-oc/

30/10/2017 www.pdf-archive.com

Adelina visualcv resume 67%

Telepat I've been working in various projects involving technologies PySpark, Apache Airflow, Docker, Tensorflow, DC/OS, Ansible and a large suite of services offered by AWS such as Redshift, Kinesis, SQS, ECS and ECS) january 2017 - april 2017 Mobile Developer Intern BlitzAtelier I've been working on both Android and IOS mobile applications using Java and Swift.

https://www.pdf-archive.com/2018/05/03/adelina-visualcv-resume/

03/05/2018 www.pdf-archive.com

Installation instructions 65%

❏ Photo​ ​of​ ​under​ ​cabinet​ ​airflow​ ​divider​ ​(See​ ​page​ ​7) ❏ Photos​ ​of​ ​cabinet​ ​dimensions​ ​(See​ ​page​ ​5.​ ​verify​ ​L/W/H​ ​using​ ​tape measure) *All​ ​page​ ​references​ ​are​ ​taken​ ​from​ ​the​ ​pre-installation​ ​guide.

https://www.pdf-archive.com/2017/10/27/installation-instructions/

27/10/2017 www.pdf-archive.com

Specifications 64%

Features and benefits • Patented airfoil system includes six airfoils and cuffed winglets that maximize performance and efficiency • Industrial-grade motor and gearbox offers efficient, reliable and durable operation • Weighs less than 145 lb (65.8 kg) allowing for easy positioning and installation • Factory-wired motor and controller cable with optional power cord plug • Perfect for spaces up to 70 x 70-ft (21.3 x 21.3-m) and ceilings as low as 14-ft (4.3-m) • Year-round energy savings, up to 10° cooling effect in hot weather and 1% energy savings per foot of ceiling height in cold weather The unique aerodynamic design enhances both energy efficiency and airflow by eliminating vortex formation at the airfoil tips.

https://www.pdf-archive.com/2016/06/24/specifications/

24/06/2016 www.pdf-archive.com

Maserati CPO Booklet UPDATES 3 3 64%

Fuel System ◗ Fuel tank, fuel filler, fuel pump, fuel lines, accumulator, pressure regulator, injectors, airflow sensor, intake manifold, temperature sensors, idle stabilizer valve, mass airflow sensor.

https://www.pdf-archive.com/2017/01/04/maserati-cpo-booklet-updates-3-3/

04/01/2017 www.pdf-archive.com

Michael Spector - CV 57%

❏ Developed​ ​an​ ​automated​ ​pipeline​ ​for​ ​maps​ ​routing​ ​engine​ ​(using​ ​Airflow,​ ​Terraform,​ ​AWS).

https://www.pdf-archive.com/2017/10/01/michael-spector-cv/

01/10/2017 www.pdf-archive.com

NC Brochure 07 57%

Eased inlet fan cylinder—ensures full area, low turbulent airflow through the cylinder.

https://www.pdf-archive.com/2015/09/25/nc-brochure-07/

25/09/2015 www.pdf-archive.com

G4SM-23RL 53%

• Sealed, cast iron, self-lubricating evaporator fan motor(s) and larger fan blades give True merchandisers a more efficient low velocity, high volume airflow design.

https://www.pdf-archive.com/2014/02/04/g4sm-23rl/

04/02/2014 www.pdf-archive.com

Specification Data sheet CM 202 E 52%

(1.60 m) • Probe for core temperature measurement • Temperature probe integral with unit (cannot be lost) • Demand-related energy supply • Integral hand shower with infinitely variable regulation, automatic retracting system and integral water shut-off function • Automatic, active rinsing and drainage of steam generator by pump • De-scaling program • Integral, maintenance-free grease extraction system with no additional grease filter • Cool down function for fast cabinet fan cooling • Integral fan impeller brake • Rear-ventilated double glass doors, hinged inside pane for easy cleaning • Cooking cabinet doors with integral sealing mechanism, no steam escape or energy loss when operated without mobile oven rack • Door handle and slam function • 2 door locking positions • Proximity door contact switch • Seamless hygienic cooking cabinet with rounded corners • Press-fit user-replaceable cabinet seal • Airflow-optimized cooking cabinet • Swivel air baffle with quick-release locks • Halogen cooking cabinet lighting with shock-proof CERAN glass • Microprocessor-controlled cooking process • Buzzer • Free time selection from 0-24 hours • Temperature unit-adjustable in °C or °F • Automatic drain condensate cooling/quenching • Lengthwise loading for accessories • Mobile oven rack with tandem steering casters, 2 casters with wheel locks, wheel diameter 5"

https://www.pdf-archive.com/2014/03/07/specification-data-sheet-cm-202-e/

07/03/2014 www.pdf-archive.com

Botanicaire Brochure V.7 20120705 52%

Botanicaire’s combined power of Nuvoc microbes TM, specialised plants, dynamic airflow and activated carbon filtration protects you and your family from these environmental toxins.

https://www.pdf-archive.com/2013/07/20/botanicaire-brochure-v-7-20120705/

20/07/2013 www.pdf-archive.com

nissan ecu tuning basics german 51%

Ändern des Luftmassenmessers (Changing Airflow Meter) ..................................................................

https://www.pdf-archive.com/2011/12/19/nissan-ecu-tuning-basics-german/

19/12/2011 www.pdf-archive.com

Specification Data sheet SelfCooking Center 201 E 47%

• Level of scaling in the steam generator is monitored and displayed • Automatic, active rinsing and drainage of steam generator by pump • Lime-scale level of steam generator automatically sensed, automatic indication of when de-scaling is necessary, lime-scale level displayed at any time • Menu-guided de-scaling program • Integral, maintenance-free grease extraction system with no additional grease filter • Cool down function for fast cabinet fan cooling • Integral fan impeller brake • Rear-ventilated double glass doors, hinged inside pane for easy cleaning • Cooking cabinet doors with integral sealing mechanism, no steam escape or energy loss when operated without mobile oven rack • Door handle and slam function • 2 door locking positions • Proximity door contact switch • Seamless hygienic cooking cabinet with rounded corners • Press-fit user-replaceable cabinet seal • Airflow-optimized cooking cabinet • Swivel air baffle with quick-release locks • Halogen cooking cabinet lighting with shock-proof CERAN glass • Microprocessor-controlled cooking process • HACCP data 10-day memory and output via integral USB interface • Adjustable buzzer tone • Adjustable foreign languages display • Adjustable display contrast • Real time display • Free time selection with delayed start from 0-24 hours • Pre-selected starting time adjustable for time and date • Function Delta-T cooking • Temperature unit-adjustable in °C or °F • Half power setting • Automatic drain condensate cooling/quenching • Lengthwise loading for accessories • Mobile oven rack with tandem steering casters, 2 casters with wheel locks, wheel diameter 5"

https://www.pdf-archive.com/2014/03/07/specification-data-sheet-selfcooking-center-201-e/

07/03/2014 www.pdf-archive.com

making 46%

To me what a pipe looks like is of secondary importance, its internal structure is far more important, this is commonly referred to as the ’airflow’ school of thought.

https://www.pdf-archive.com/2010/11/27/making/

26/11/2010 www.pdf-archive.com

Specification Data sheet SelfCooking Center 62 E 46%

• Level of scaling in the steam generator is monitored and displayed • Automatic, active rinsing and drainage of steam generator by pump • Lime-scale level of steam generator automatically sensed, automatic indication of when de-scaling is necessary, lime-scale level displayed at any time • Menu-guided de-scaling program • Integral, maintenance-free grease extraction system with no additional grease filter • Cool down function for fast cabinet fan cooling • Integral fan impeller brake • Rear-ventilated double glass doors, hinged inside pane for easy cleaning • Door handle with right/left and slam function • 2 door locking positions • Proximity door contact switch • Seamless hygienic cooking cabinet with rounded corners • Press-fit user-replaceable cabinet seal • Airflow-optimized cooking cabinet • Swivel air baffle with quick-release locks • Drip collector and door drip pan with continuous discharge to unit drain • Halogen cooking cabinet lighting with shock-proof CERAN glass • Microprocessor-controlled cooking process • HACCP data 10-day memory and output via integral USB interface • Adjustable buzzer tone • Adjustable foreign languages display • Adjustable display contrast • Real time display • Free time selection with delayed start from 0-24 hours • Pre-selected starting time adjustable for time and date • Function Delta-T cooking • Temperature unit-adjustable in °C or °F • Half power setting • Automatic drain condensate cooling/quenching • Lengthwise loading for accessories • Hinging rack with additional rail for drip collector, rail distance 2 5/8"

https://www.pdf-archive.com/2014/03/07/specification-data-sheet-selfcooking-center-62-e/

07/03/2014 www.pdf-archive.com

bmw evp brochure 44%

fuel injection and airflow sensors.

https://www.pdf-archive.com/2013/02/25/bmw-evp-brochure/

25/02/2013 www.pdf-archive.com

Installation Guide 44%

6 Understanding Airflow Patterns..................................................................................7 Installation Overview..........................................................................................................................

https://www.pdf-archive.com/2016/06/24/installation-guide/

24/06/2016 www.pdf-archive.com

Newsletter Winter 2015 Final (1) 43%

Dirty filters will restrict airflow and increase energy use.

https://www.pdf-archive.com/2015/12/10/newsletter-winter-2015-final-1/

10/12/2015 www.pdf-archive.com

TRH-2003-super-hotspot-station 42%

 High airflow allows pressure equalization to prevent stress on enclosure seals, ultimately lowering enclosure design and manufacturing costs.

https://www.pdf-archive.com/2015/01/24/trh-2003-super-hotspot-station/

24/01/2015 www.pdf-archive.com