BO66JXX640DT1
XFP CWDM 10G 1270 – 1450nm 40KM
RoHS Compliant Optical Transceiver
XFP CWDM 10G 1270 – 1450nm Single mode Optical Transceiver
Features
Description
The BlueOptics© BO66JXX640DT1 XFP transceiver is a
high performance, cost effective module supporting a
datarate up to 10Gbps with 40 Kilometer link length
on single mode fiber.
10Gb/s serial optical interface to 802.3ae
10GBase-ER
DFB laser transmitter 1270nm – 1450nm
BlueOptics© transceivers are 100% compliant with
XFP Multi-Source Agreement (MSA).
PIN photo-detector
All BlueOptics© XFP transceivers are always equipped
with digital diagnostic function compliant to MSA SFF8472.
Hot-pluggable XFP footprint compliant to
INF-8077
Duplex LC/UPC
interface
Using digital diagnostic, BlueOptics© XFP transceivers
provide the following real time information:
2-wire interface for management
Metal enclosure, for lower EMI
RoHS compliant and lead-free
Single +3.3V power supply
Compliant with SFF-8472
Case operating temperature
Supply voltage
Laser bias current
Laser average output power
Laser received input power
Temperature
The transceiver consists of five sections: A DFB
transmitter, a PIN photodiode, a trans-impedance
preamplifier (TIA), the LD Driver and the digital
diagnostic function.
-
Applications
10GBase-ER/EW
10G Ethernet
-1-
type
pluggable
Commercial: 0°C to +70°C
Extended: -10°C to +80°C
Industrial: -40°C to +85°C
optical
BO66JXX640DT1
XFP CWDM 10G 1270 – 1450nm 40KM
RoHS Compliant Optical Transceiver
Warnings
Order Information
Handling Precautions: This device is susceptible to
damage as a result of electrostatic discharge (ESD). A
static free environment is highly recommended.
Laser Safety: Even small radiation emitted by laser
devices can be dangerous to human eyes and lead to
permanent eye injuries. Be sure to avoid eye contact
with direct or indirect radiation.
Part No.
BO66JXX640DT1
DDM
0°C to +70°C
BO66JXX640DT1EX
-10°C to +80°C
BO66JXX640DT1IN
-40°C to +80°C
XX can be following Wavelength:
Warranty
Every BlueOptics© transceiver comes with a 5 year
replacement warranty and lifetime support.
For a warranty inquiry, please contact your CBO sales
representative.
This warranty only covers the first user of the
equipment.
Temp.
Wavelength
xx
Wavelength
xx
1270nm
27
1370nm
37
1290nm
29
1390nm
39
1310nm
31
1410nm
41
1330nm
33
1430nm
43
1350nm
35
1450nm
45
Standard
Co.
Regulatory Compliance
Feature
Important Notice
Electrostatic
- IEC/EN 61000-4- 2
Performance figures, data and any illustrative
material provided in this data sheet are typical and
must be specifically confirmed in writing by CBO
before they become applicable to any particular order
or contract. In accordance with the CBO policy of
continuous improvement specifications may change
without notice.
Electromagnetic
- FCC Part 15 Class B EN 55022
Interference (EMI)
- Class B (CISPR 22A)
Laser Eye Safety
- FDA 21CFR 1040.10, 1040.11
- IEC/EN 60825-1, 2
Discharge (ESD)
The publication of information in this data sheet does
not imply freedom from patent or other protective
rights of CBO or others.
Further details are available from any CBO sales
representative.
Installation
Before installation attach an ESD-preventive wrist to
ensure not to damage the transceiver or hardware.
BlueOptics© BO66JXX640DT1 can be installed in any
Small Form Factor Pluggable+ (XFP) port. You can
install the BO66JXX640DT1 regardless if the system is
powered on or off, because it is hot-swappable.
Insert the transceiver into the XFP port and remove
the dust cap.
You can now connect your cable.
-2-
Component
Recognition
- IEC/EN 60950, UL
RoHS
- 2002/95/EC
EMC
- EN61000-3
Class 1
BO66JXX640DT1
XFP CWDM 10G 1270 – 1450nm 40KM
RoHS Compliant Optical Transceiver
1. Absolute Maximum Ratings
Parameter
Storage Temperature
Storage Ambient Humidity
Symbol
Ts
HA
Min.
-40
5
Typ.
Max.
85
95
Unit
ºC
%
2. Recommended Operating Conditions
Parameter
Case Operating Temperature
Ambient Humidity
Transmission Distance
Coupled Fiber
Symbol
Tcase
HA
Min.
0
-10
-40
5
Typ.
Max.
70
80
85
70
40
Unit
ºC
Note
BO66HXX640DT1
BO66HXX640DT1EX
BO66HXX640DT1IN
%
KM
Single mode fiber
9/125µm SMF
3. Electrical Interface Characteristics
Parameter
Power Supply Voltage
Signal Input Voltage
Transmitter
Input differential impedance
Single ended data input swing
Transmit Disable Voltage
Transmit Enable Voltage
Transmit Disable Assert Time
Receiver
Differential data output swing
Data output rise time
Data output fall time
LOS Fault
LOS Normal
Power Supply Rejection
Symbol
Vcc
Icc
Min.
3.13
Rin
Vin,pp
VD
VEN
Vout,pp
tr
tf
VLOS
fault
VLOS
norm
PSR
Typ.
3.3
Max.
3.45
450
100
120
2.0
GND
340
650
Unit
V
mA
Note
Ω
1
820
Vcc
GND+0.8
10
mV
V
V
µs
850
40
40
Vcc-0.5
VccHOST
mV
Ps
Ps
V
GND
GND+0.8
V
100
Notes:
1. Internally AC coupled.
2. Or open circuit.
3. Into 100Ω differential termination.
4. 20-80%
5. LOS is an open collector output. Should be pulled up with 4.7KΩ on the host board.
6. Section 2.7.1. XFP MSA Specification
-3-
mVpp
2
3
4
4
5
5
6
BO66JXX640DT1
XFP CWDM 10G 1270 – 1450nm 40KM
RoHS Compliant Optical Transceiver
4. Transmitter Specifications - Optical
Parameter
Average Output Power
Extinction Ratio
Center Wavelength
SMSR
Transmitter and Dispersion Peanlty
RIN
1.
Symbol
POUT
ER
λC
Min.
0
3.5
λ-6.5
30
Typ.
Max.
5
λ
λ+6.5
Unit
dBm
dB
nm
2
-130
dB
dB/Hz
Max.
1610
-15.5
Unit
nm
dBM
dBm
dBm
dBm
dB
TDP
RIN
Note
1
Notes:
λ is 1270,1290,1310,1330,1350,1370,1390,1410,1430 or 1450
5. Receiver Specifications - Optical
Parameter
Input Optical Wavelength
Receiver Sensitivity
Input Saturation Power (Overload)
LOS Assert
LOS De-assert
LOS Hysteresis
1.
Symbol
λIN
PIN
PSAT
PA
PD
Min.
1270
Typ.
0.5
-28
-22
0.5
Note
1
Notes:
-12
31
Measured with 10Gb/s; BER =<10 @PRBS=2 -1 non-return-to-zero.
6. XFP to Host Connector Pin Out
Pin
1
2
3
Symbol
GND
VEE5
Mod-Desel
4
Interrupt
5
6
7
8
9
10
11
12
TX_DIS
VCC5
GND
VCC3
VCC3
SCL
SDA
Mod_Abs
13
Mod_NR
14
15
16
17
RX_LOS
GND
GND
RD-
Name / Description
Module Ground
Optional –5.2 Power Supply – Optional
Module De-select; When held low allows the module to respond to 2wire serial interface commands
Interrupt (bar); Indicates presence of an important condition which can
read over the serial 2-wire interface
Transmitter Disable; Transmitter laser source turned off
+5 Power Supply – Optional
Module Ground
+3.3V Power Supply
+3.3V Power Supply
Serial 2-wire interface clock
Serial 2-wire interface data line
Module Absent; Indicates module is not present. Grounded in the
module.
Module Not Ready; CBO defines it as a logical OR between RX_LOS
and Loss of Lock in TX/RX.
Receiver Loss of Signal indicator
Module Ground
Module Ground
Receiver inverted data output
-4-
Note
1
2
1
2
2
2
2
1
1
BO66JXX640DT1
XFP CWDM 10G 1270 – 1450nm 40KM
RoHS Compliant Optical Transceiver
18
19
20
21
RD+
GND
VCC2
P_Down/RST
22
23
24
VCC2
GND
RefCLK+
25
RefCLK-
26
27
28
29
30
GND
GND
TDTD+
GND
Receiver non-inverted data output
Module Ground
+1.8V Power Supply – Optional
Power Down; When high, places the module in the low power stand-by
mode and on the falling edge of P_Down initiates a module reset
Reset; The falling edge initiates a complete reset of the module
including the 2-wire serial interface, equivalent to a power cycle
+1.8V Power Supply – Optional
Module Ground
Reference Clock non-inverted input, AC coupled on the host board –
Optional
Reference Clock inverted input, AC coupled on the host board –
Optional
Module Ground
Module Ground
Transmitter inverted data input
Transmitter non-inverted data input
Module Ground
1
1
3
3
1
1
1
Notes:
1.
2.
3.
Module circuit ground is isolated from module chassis ground within the module.
Open collector; should be pulled up with 4.7kΩ – 10kΩ on host board to a voltage between 3.15V and
3.6V.
Reference Clock input not required. If present, it will be ignored.
Pinout of Connector Block on Host Board
-5-
BO66JXX640DT1
XFP CWDM 10G 1270 – 1450nm 40KM
RoHS Compliant Optical Transceiver
7. EEPROM Information
The SFP MSA defines a 256-byte memory map in EEPROM describing the transceivers capabilities, standard
interfaces, manufacturer, and other information, which is accessible over a 2 wire serial interface at the 8-bit
address 1010000X (A0h).
Data
Address
Field Size
(Bytes)
Name of Field
Contents (Hex)
Description
Formfactor
128
129
130
131-138
1
1
1
8
Identifier
Ext. Identifier
Connector
Transceiver
139
140
1
1
Encoding
BR-Min
XX
XX
XX
XX XX XX XX XX XX XX
XX
XX
XX
141
1
BR-Max
XX
142
1
143
144
145
146
147
1
1
1
1
1
16
XX
Length (9μm) km
184-185
186-187
2
2
Vendor rev
Wavelength
XX
XX
XX
XX
XX
XX XX XX XX
XX XX XX XX
XX XX
XX
XX XX XX
XX XX XX XX
XX XX XX XX
XX XX
XX XX XX XX
XX XX
188 – 189
2
Wavelength tolerance
XX
190
1
191
1
192-195
4
148-163
164
165-167
Length (9μm) 100m
Length (50μm) 10m
Length(62.5μm)10m
Length (Copper)
Device Tech
Vendor name
1
3
16
168-183
CDR Support
Vendor OUI
Vendor PN
XX XX XX
XX XX XX
XX XX XX
XX XX XX
XX
CC BASE
XX XX XX XX
Power Supply
196-211
16
Vendor SN
XX XX XX XX XX XX XX
XX XX XX XX XX XX XX
XX XX
-6-
Minimum bit rate,
units of 100 MBits/s
Maximum bit rate,
units of 100 MBits/s
Max. link length in
KM
Max. link length in M
Max. link length in M
Max. link length in M
Max. link length in M
Device technology
Vendor name - OEM
CDR Rate Support
XX
Max Case Temp
Transmittter Code
Product Number
depending on Part
-
Vendor revision
Transceiver
Wavelength
Guaranteed range of
laser wavelength
Checksum of bytes 062
Checksum of bytes 062
Power supply current
requirements
and
max
power
dissipation
Part serial number
BO66JXX640DT1
XFP CWDM 10G 1270 – 1450nm 40KM
RoHS Compliant Optical Transceiver
212-219
8
220
1
221
1
Vendor date code
Diagnostic Monitoring
Type
XX XX XX XX XX XX 20
20
XX XX XX XX XX XX 20
20
XX
Year, Month, Day
XX
Defines
quantities
reported by Aux. A/D
channels
Check code for the
Extended ID Fields
Enhanced Options
222
1
Aux Monitorin
223
1
224-255
32
XX
CC_EXT
XX XX XX XX
XX XX XX XX
XX XX XX XX
XX XX XX XX
XX XX XX XX
Vendor Specific
XX
XX
XX
XX
XX
XX
XX
XX
Year, Month, Day
Indicates which
optional enhanced
features are
implemented (if any)
in
the transceiver
XX
XX
XX
XX
8. Digital Diagnostics / Digital Optical Monitoring
The transceiver provides serial ID memory contents and diagnostic information about the present
operating conditions by the 2-wire serial interface (SCL, SDA).
The diagnostic information with internal calibration or external calibration are all implemented,
including received power monitoring, transmitted power monitoring, bias current monitoring, supply
voltage monitoring and temperature monitoring.
-7-
BO66JXX640DT1
XFP CWDM 10G 1270 – 1450nm 40KM
RoHS Compliant Optical Transceiver
9. Mechanical Specifications (Unit: mm)
Contact Information
CBO GmbH
Friedhofstraße 25
45478 Mülheim an der Ruhr
Germany
Tel.:
Fax.:
eMail:
web:
0049 – 208 – 777 247 - 0
0049 – 208 – 777 247 - 99
info@cbo-it.de
www.cbo-it.de
-8-
Link to this page
Permanent link
Use the permanent link to the download page to share your document on Facebook, Twitter, LinkedIn, or directly with a contact by e-Mail, Messenger, Whatsapp, Line..
Short link
Use the short link to share your document on Twitter or by text message (SMS)
HTML Code
Copy the following HTML code to share your document on a Website or Blog